Get in touch with Qilida

Contact Form Demo
products backgrounds

Instrument transformer comprehensive test category

Qilida Solutions

Instrument Transformer Comprehensive Tester

The Instrument Transformer Comprehensive Tester is a professional-grade device for testing and analyzing current (CT) and potential transformers (PT) with exceptional accuracy and efficiency. Combining advanced measurement technology, automated testing, and intelligent diagnostics, it simplifies testing processes while delivering precise results. Ideal for utility companies, substations, manufacturers, and labs, it offers reliable, lab-quality performance even in field conditions.

Enquiry Today

Advanced Testing Capabilities

Ratio & Accuracy Testing

Precise measurement of transformation ratios and accuracy class verification. Ensures metering accuracy from 0.1% to 3% class specifications with automated calculation of ratio errors.

Polarity Verification

Instantaneous polarity testing to ensure correct phase relationships. Critical for proper relay coordination and preventing reverse power flow indications in protection systems.

Burden Testing

Measures actual connected load on transformer secondary. Verifies that the burden doesn't exceed rated values, ensuring accuracy is maintained under real operating conditions.

Insulation Resistance

High-voltage insulation testing (typically 1000-5000V DC) to verify dielectric integrity. Detects moisture ingress, contamination, and aging that could lead to failures.

Saturation Curve Analysis

Excitation characteristic measurement for CTs. Identifies knee-point voltage to ensure proper operation during fault conditions and prevent relay mal-operation.

Phase Angle Error

Measures phase displacement between primary and secondary. Critical for power metering accuracy and revenue calculations, especially in precision 0.1 and 0.2 class applications.

Solving Critical Testing Challenges

Common Pain Points
Revenue losses from billing errors, disputed utility charges, and undetected energy theft cost millions annually.
Incorrect CT/PT operation causes relay mal-trips or failure to trip during faults, leading to equipment damage and dangerous safety incidents.
Unplanned outages from insulation breakdown or winding failures cause costly downtime, emergency repairs, and loss of critical power supply.
Non-compliance with IEC, IEEE, and ANSI standards leads to failed inspections, regulatory penalties, and voided equipment warranties.
Our Solutions
Our ratio and phase angle testing ensure 0.1-0.2% accuracy-class compliance, eliminating metering errors and protecting revenue streams with certified, traceable measurements.
Comprehensive polarity verification, saturation curve analysis, and burden testing ensure protective relays receive accurate signals for reliable fault detection and clearance.
Proactive insulation resistance and winding resistance testing detect degradation early, enabling condition-based maintenance and preventing catastrophic failures.
Our testing protocols align with IEC 61869, IEEE C57.13, and ANSI C12 standards, providing compliant documentation and certification for audits and approvals.

Applications of the Instrument Transformer Comprehensive Tester

Trusted by professionals across diverse industries.

Power Generation

Power Utilities

Substation commissioning, routine maintenance, and transformer asset management programs.

Transmission & Distribution

Testing Laboratories

Calibration services, third-party certification, and research & development.

Industrial Facilities

EPC Contractors

Project commissioning, site acceptance testing, and installation verification.

Power Generation

Industrial Facilities

On-site maintenance, predictive diagnostics, and equipment lifecycle management.

Transmission & Distribution

Service Companies

Field service operations, repair verification, and maintenance contracts.

Industrial Facilities

Renewable Energy

Wind farms, solar plants, and distributed generation system testing.

What Our Clients Say

John Mitchell

The Qilida comprehensive test system has transformed our substation maintenance operations. We've reduced testing time by 65% while actually improving measurement accuracy. The automated reporting alone saves us countless hours every month.

James Morrison

Senior Electrical Engineer, Pacific Power & Light

Sarah Chen

After extensive evaluation of competing systems, Qilida's solution stood out for its exceptional accuracy and ease of use. The all-in-one design eliminated our need for multiple test sets, and the field portability is genuinely impressive.

Sarah Chen

Testing Lab Director, MegaGrid Solutions

Robert Patterson

We've deployed Qilida test systems across 15 substations, and the consistency is remarkable. The automated test sequences ensure every technician follows best practices, and the cloud data management has simplified our compliance reporting dramatically.

Rajesh Kumar

Head of Asset Management, National Grid India

Why Choose QilidaDiscover the benefits of the Instrument Transformer Comprehensive Test category, designed for accurate and efficient transformer testing.

Industry-Leading Innovation: 20+ years of R&D excellence in power testing technology. Our engineering team holds 45+ patents.
Global Standards Compliance: Full certification to IEC 61869, IEEE C57.13, ISO 9001, and CE marking.
Proven Track Record: Trusted by 500+ utilities and testing laboratories across 60 countries. Over 10,000 systems deployed globally with a 99.2% customer satisfaction rating.
Comprehensive Support: 24/7 technical support with multilingual expertise.
Future-Proof Technology: Regular firmware updates, expandable functionality, and backward compatibility protect your investment.