Get in touch with Qilida

Dielectric Loss Detection Category
Showing all 4 results
Advanced Features That Solve Your Problems
Technology designed for accuracy, reliability, and ease of use
Frequency conversion and Fourier transform digital filtering ensure accurate measurements in high-noise substation environments with up to 200% interference.
Fully automatic testing with self-calibration and digital waveform analysis. No manual bridge balancing or complex calculations required.
Measure dielectric loss on energized capacitive equipment without disconnection, minimizing operational disruption and safety risks.
Integrated three-terminal SF6 standard capacitors provide accuracy unaffected by temperature and humidity, ensuring consistent results over years of use.
Support for series/parallel measurement, CVT self-excitation testing, and simultaneous C1/C2 capacitance measurement with automatic compensation.
Large LCD display with backlight, built-in thermal printer, USB connectivity, and automatic data storage with timestamp for compliance documentation.
Multi-level protection including high-voltage cutoff, ground detection, power supply protection, and overload prevention for operator safety.
Integrated temperature control for transformer oil testing (0-125°C) with PID algorithm and medium-frequency induction heating for uniform results.
Are You Facing These Critical Challenges?
Applications of Dielectric Loss Detection Systems

Power Utilities
Transmission and distribution transformers, bushings, and capacitive voltage transformers (CVTs)

Industrial Facilities
Manufacturing plants, data centers, and critical infrastructure requiring reliable power quality

Renewable Energy
Solar farms, wind power stations, and energy storage systems with power conversion equipment

Electric Vehicles
Charging infrastructure, battery management systems, and high-voltage power electronics

Healthcare
Hospital power systems, medical imaging equipment, and radiation therapy machines

Aerospace
Aircraft electrical systems, ground support equipment, and testing facilities
What Our Clients Say

"The anti-interference capability is truly impressive. We can now test our 220kV CVTs without taking them offline, which has saved us hundreds of thousands in lost revenue from planned outages."
Michael
Chief Engineer, Pacific Power Utilities

"The system detected moisture ingress in our main transformer three months before it would have failed catastrophically. The early warning prevented a $1.2 million emergency replacement and kept our plant running."
Sarah
Maintenance Director, Advanced Manufacturing Corp

"We've reduced our annual testing costs by 65% while actually improving our asset monitoring coverage. The automated compliance reporting alone saves our team 200 hours per year."
James
Asset Management Lead, Regional Energy Network
Why Choose QilidaOver 15 years of transformer testing expertise with 10,000+ successful installations worldwide across 50+ countries.